FTO+ filter
Independent tests · Envirotek Laboratory LLC

Tested on more than 200 contaminants

The Coldstream FTO+ filter (ref. CF163W) has been independently tested over a full capacity of 3,000 litres.

NSF/ANSI 42 NSF/ANSI 53 NSF P-231 NSF/ANSI 401 IAPMO ANAB Accredited
Overview

Results at a glance

Each value was measured by Envirotek Laboratory LLC over 3,000 litres under NSF/ANSI protocols.

99,9999%
Bacteria
NSF P-231 · 6-log
99,9985%
Virus
NSF P-231 · 5-log
99,94%
Cysts
NSF P-231 · Giardia
99,35%
Lead
NSF/ANSI 53
>99,8%
Pesticides
NSF/ANSI 53 · 70+ molecules
>97%
Pharmaceuticals
NSF/ANSI 401 · 30+ molecules
97,9%
Copper
NSF/ANSI 53
80%
Free chlorine
NSF/ANSI 42
Validated
HAA acids
NSF/ANSI 53 · 5 acides
Technical sheet

Tested filter characteristics

Coldstream FTO+ filter by KLT Filtration Ltd.

Model Coldstream FTO+ (ref. CF163W)
Laboratory Envirotek Laboratory LLC · ANAB AT-2866 · IAPMO #000102 · EPA NJ01298
Standards NSF/ANSI 42 · NSF/ANSI 53 · NSF P-231 · NSF/ANSI 401
NSF Certificate C0091750
Tested capacity 3,000 litres
Reports Envirotek #19-69 (2019) · #21-103-2-KLT (2021)
NSF P-231

Micro-organisms

Most stringent microbiological protocol on the market

Bacteria: 99.9999% reduction

6-log level: for every million bacteria present, fewer than one passes through the filter.

Volume Influent (UFC) Effluent (UFC) Result
500 L 328 646 000 74 6-log
1 500 L 328 646 000 120 6-log
3 000 L 328 646 000 360 6-log

Virus: 99.9985% reduction

5-log protection maintained throughout the filter lifespan (Rotavirus).

Volume Influent (PFU) Effluent (PFU) Result
500 L 24 642 000 80 Pass
1 500 L 24 642 000 360 Pass
3 000 L 24 642 000 610 Pass

Cysts: 99.94% reduction

Giardia and Cryptosporidium are chlorine-resistant, a risk even in treated networks.

Volume Influent Effluent Result
500 L 1 542 000 870 Pass
1 500 L 1 542 000 310 Pass
3 000 L 1 542 000 786 Pass
NSF/ANSI 42

Chlorine and disinfectants

Taste and odour reduction

80%

Free chlorine

Influent 2 mg/L · Max effluent 0.39 mg/L at 3,000 L

87,5%

Chloramine

Influent 3.2 mg/L · Max effluent 0.4 mg/L at 3,000 L

NSF/ANSI 53

Heavy metals

Reduction of health-risk contaminants

Up to 99.35% reduction
Metal Influent (µg/L) Max effluent Reduction Result
Lead 154 <1 µg/L 99,35% Very effective
Copper 2 810 64,3 µg/L 97,9% Very effective
Barium 9 875 592 µg/L 94% Very effective
Iron 3 865 232 µg/L 94% Very effective
Nickel 100 2,7 µg/L 97,8% Very effective
Manganese 1 335 305 µg/L 77% Effective
Mercury 6 2,8 µg/L 53% Partial
Arsenic 48,2 34,3 µg/L 29% Low
Very effective (>75%)Partial (25-75%)Low (<25%)
NSF/ANSI 53

Pesticides and herbicides

70+ molecules tested

>99.8% for virtually all molecules
Family Examples Reduction Result
Organochlorines Dieldrine, DDT, Chlordane >99,8% Very effective
Triazines Atrazine, Simazine >99,8% Very effective
Chloroacetanilides Alachlore, Metolachlore >99,8% Very effective
Acid herbicides 2,4-D, Dicamba >99,4% Very effective
PCBs Polychlorinated biphenyls >99,8% Very effective
NSF/ANSI 53

Volatile organic compounds

50+ molecules tested

Contaminant Reduction Result
Vinyl chloride >99,5% Very effective
Tetrachloroethylene >99,8% Very effective
Toluene, Xylenes, Styrene >99,3% Very effective
Total trihalomethanes 74,4% Effective
Chloroform 65% Partial
Benzene 29% Low
MTBE 30% Low
Very effective (>75%)Partial (25-75%)Low (<25%)
NSF/ANSI 401

Pharmaceutical residues and endocrine disruptors

30+ drugs, hormones and industrial chemicals

>97% for the majority of molecules
Contaminant Reduction Result
17-beta-Oestradiol >99,9% Very effective
17-alpha-Ethinylestradiol >99,6% Very effective
Carbamazepine 99,99% Very effective
Ibuprofene 97,7% Very effective
Bisphenol A (BPA) 98,4% Very effective
Diclofenac >99,5% Very effective
Triclosan >99,2% Very effective
TCEP 99% Very effective
DEET 98,9% Very effective
Testosterone 92,9% Very effective
NSF/ANSI 53

Haloacetic acids (HAAs)

By-products of chlorine disinfection

5 acids tested: all validated over 3,000 L
Haloacetic acid EPA limit (µg/L) Max effluent Result
Monochloroacetic acid 6 1,7 Validated
Monobromoacetic acid 6 1,6 Validated
Dichloroacetic acid 0,7 0,2 Validated
Bromochloroacetic acid 6 0,6 Validated
Trichloroacetic acid 6 0,6 Validated
Transparency

What the filter does not reduce

Complete results, unfiltered

Contaminants with low reduction (<35%):

Nitrates (29.6%): Ionic nitrates are not retained by activated carbon.

Sulphates (2.4%): Almost not reduced, which is positive as sulphates contribute to the natural minerality of the water.

Fluorides (4.5%): Not significantly reduced.

Arsenic (28.8%): Partial reduction only.
Downloads

Official reports

Laboratory documents and NSF certification

NSF/ANSI 53 · Envirotek 2021

Haloacetic Acids

Full test of 5 HAAs over 3,000 litres. All acids validated below EPA thresholds.

View PDF →
NSF 42, 53, P-231, 401 · Envirotek 2019

200+ Contaminants

Full report: bacteria, viruses, metals, pesticides, pharmaceuticals over 3,000 L.

View PDF →
NSF 42, 53, P-231 · Envirotek 2019

Supplementary Tests

2019 supplementary report covering standards 42, 53 and P-231 on the same filter.

View PDF →
NSF International · Officiel

NSF Certificate

Official NSF, IAPMO and ANAB certification for the Coldstream FTO+ filter (C0091750).

View PDF →

These results correspond to the Coldstream FTO+ filter (ref. CF163W) tested under the conditions described in the Envirotek reports (#19-69, 2019 and #21-103-2, 2021). Actual performance may vary depending on source water quality, temperature and usage conditions.